Output: 12V 7A ;5V 3A 99W
Input: 88~132VAC/176~264VAC by switch 248~373VDC
Warranty: 2 years
Certificates: UL,CB,EMC,ROHS
MODEL |
NED-100C |
||
OUTPUT |
OUTPUT NUMBER |
CH1 |
CH2 |
DC VOLTAGE |
12V |
5V |
|
RATED CURRENT |
7A |
3A |
|
CURRENT RANGE Note. |
0~ 8A |
0 ~ 3A |
|
RATED POWER |
99W |
||
RIPPLE&NOISE (max.)Note.2 |
120mVp-p |
80mVp-p |
|
VOLTAGE ADJ. RANGE |
CH1: 11.4~ 13.2V |
||
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±3.0% |
|
LINE REGULATION Note.4 |
±0.5% |
±0.5% |
|
LOAD REGULATION Note.5 |
±1.0% |
±2.0% |
|
SETUP, RISE TIME |
2000ms,30ms/230VAC ,1200ms, 30ms/115VAC at full load |
||
HOLD UP TIME (Typ.) |
25ms/230VAC 20ms/115VAC at full load |
||
INPUT |
VOLTAGE RANGE |
88 ~ 132VAC / 176~264VAC selected by switch 248 ~ 373VDC |
|
FREQUENCY RANGE |
47~63HZ |
||
EFFICIENCY (Typ.) |
80% |
||
AC CURRENT (Typ.) |
2A/115VAC 1.2A/230VAC |
||
INRUSH CURRENT (Typ.) |
COLD START 45A |
||
LEAKAGE CURRENT |
<2mA/240VAC |
||
PROTECTION |
OVER LOAD |
110~150% rated output power |
|
Protection type:Hiccup mode, recovers automatically after fault condition is removed |
|||
OVER VOLTAGE |
CH1: 13.8 ~ 15.8V |
||
Protection type:Hiccup mode, recovers automatically after fault condition is removed |
|||
ENVIRONMENT |
WORKING TEMP. |
-20~+60°C (Refer to "Derating Curve") |
|
WORKING HUMIDITY |
20~90% RH non-condensing |
||
STORAGE TEMP., HUMIDITY |
-40~+85°C, 10~95%RH |
||
TEMP. COEFFICIENT |
±0.03%/°C (0 ~ 50°C) on Ch1 output |
||
VIBRATION |
10~500HZ, 2G10min/1cycle, period for 60min. each along X, Y, Z axes |
||
SAFETY&EMC (Note 7) |
SAFETY STANDARDS |
UL60950-1, CB(IEC60950-1) approved |
|
WITHSTAND VOLTAGE |
1/P-0/P:3KVAC 1/P-FG:2KVAC 0/P-FG:0.5KVAC |
||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC |
||
EMC EMISSION |
Compliance to EN55022 (CISPR22) Class B |
||
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-1, light industry level, criteria A |
||
OTHERS |
MTBF |
320.7Khrs min. MIL-HDBK-217F(25°C) |
|
DIMENSION |
199*98*38mm(L*W*H) |
||
PACKING |
0.55Kg; 30pcs / 17.5Kg / 0.97CUFT |
||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. 6. Each output can work within current range. But total output power can’t exceed rated output power. 7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” |